PALFINGER Paltronic 50 Error codes

00.
*
00System    in    normal    working condition
01.
**
00Checksum EPROM not ok Crane cannot be operated
02.
**
00Checksum EEPROM not ok Crane cannot be operated
03.
*
00
01
02
05
09
10
17
18
25
26
06
Overload on a crane load limit general (until version 2.8)
Load limit HPLS
Load limit Nominal load
Negative Load limit
Slewing 1, Load limit 1 (SHB)
Slewing 1, Load limit 2 (SHB)
Slewing 2, Load limit 1 (ISC)
Slewing 2, Load limit 2 (ISC)
Slewing   3,   Load   limit   1   (no stab.)
Slewing   3,   Load   limit   2   (no stab.)
Workman    basket    mode    not allowed.
04.
**
01
02
03
Error safety check
Internal program fault
Fault internal RAM/Register
Error controller
07.
**
00Overload on rope winch Load moment increasing movements not possible.
10.
**
00Error on emergency stop feedback.
Attention: Crane has no overload system in this condition
   
10.
**
01
02
Error emergency cut off feedback: crane
Error emergency cut off feedback: stabilizers
11.
**
00Broken connection to pressure transducer on
main boom piston side (signal less than 1.25 mA).
   
   
12.
**
00Broken connection to
pressure transducer on main boom piston rod side (signal less than 1.25 mA).
   
   
13.
**
00Broken connection to pressure transducer
on fly-jib boom piston side (signal less than 1.25 mA).
   
   
14.
**
00Broken connection to pressure transducer on fly-jib boom piston side (signal less than 1.25 mA).
   
   
15.
**
00Broken connection to level indicator on crane (B1).
16.
**
00Broken connection to level indicator on fly jib (B301).
   
   
20.
**
00Too high signal value from pressure transducer main boom piston side (U230).
21.
**
00Too high signal value from pressure transducer main boom piston rod side (U231).
22.
**
00Too high signal value from pressure transducer fly jib piston side (U236).
23.
**
00Too high signal value from pressure transducer fly jib piston side (U237).
30.
*
00
01
02
05
09
Overload on Fly Jib general (until version 2.8)
Load limit HPLS
Load limit Nominal load
Negative Lastgrenze
Reduced load limit
32.
**
00Load limit for manual extension boom reached.
41.
**
00CAN – reading buffer writing error.
42.
**
00
01
02
03
04
05
06
07
CAN Error interrupt, Bus Off .
No Specification
Stuff Error
Form Error
Acknowledge Error
Bit 1 Error
Bit 0 Error
CRC Error
unused
44.
**
00
51-5F
61-6F
71-7F
Error CAN addressing.
General
Spool position feeler boxes
Display units and RRC System Encoder
45.
**
00
01
02
03
04
05
06
07
CAN Warning interrupt, Bus Off .
No Specification
Stuff Error
Form Error
Acknowledge Error
Bit 1 Error
Bit 0 Error
CRC Error
unused
46.
**
00CAN transmitting not possible.
47.
**
00CAN receiving not possible.
   
50.
**
00
51-5F
61-6F
71-7F
Error initialisation of CAN participant
General
Spool position box Display units and RRC system
Encoder
60.
**

01
02
03
04
05
06
07
08
09
10
11
27
28
Error lever comparison
Main boom lowering
Main boom lifting
Outer boom lifting
Outer boom lowering
Slewing left
Slewing right
Extensions extending
Rope winch lifting
Fly jib outer boom lifting
Fly jib outer boom lowering
Fly jib extensions extending
Additional module active in direction A
Additional module active in direction B
61.
**

99
51
52
53
54-5F
Error CAN document from spool position box to main unit
Unknown participant
Spool position feeler crane
Spool position feeler crane fly jib
Input box for ISC
These addresses must not be used at all.
62.
**

99
51
52
53
54-5F
10 times no data diagram (100 ms)
Unknown participant
Spool position feeler crane
Spool position feeler crane fly jib
Input box for ISC
These addresses must not be used at all.
63.
**

01
02
03
04
05
06
07
08
09
10
11
27
28
Lever not in neutral position during start up.
Main boom lowering
Main boom lifting
Outer boom lifting
Outer boom lowering
Slewing left
Slewing right
Extensions extending
Rope winch Lifting
Fly-Jib outer boom
Lifting Fly-Jib outer boom lowering
Fly-Jib extensions extending
Additional module in A- direction
Additional module in B- direction
64.
**

01
03
05
09
27
Function operated in both directions
Main boom
Outer boom
Slewing
Fly-Jib knuckle boom
Additional module
65.
**
99
51
52
53
54-5F
Error initialisation of digital inputs
Unknown participant Spool position feeler crane Spool position feeler crane fly jib
Input box for ISC
These addresses must not be used at all.
66.
**
99
62-6F
Document error from display unit to basic unit Unknown participant Address of display unit
67.
**
99
62-6F
10 times no data diagram Unknown participant Address of display unit
68.
**
99Error during initialisation of display unit
Unknown participant
 62-6FAddress of display unit
  
70.
**
00 –
99
Error on data document
from RRC receiver to main unit.
   
   
71.
**
61Error 10 times no diagram on digital channels
100 ms no signal.

 

72.
**
10 times no diagram on analogue channels.
73.
**
61
99
Error of RRC initialisation (start up process)
RRC address Unknown adderss
75.
**
71-7FError document form encoder to main unit. Address of encoder.
76.
**
71-7FNo answer once per second from encoder. Address of encoder.
77.
**
71-7FAngle change too quick. Address of encoder.
78.
**
99Initialisation error of encoder.
Unknown encoder
 70-7FAddress of encoder (usually 7F).
79.
**
71-7FAngle check wrong Address of encoder (usually 7F).

 

80.
**
01
02
Service interval required. Service interval crane (until version 2.8)
Service interval rope winch
81.
*
01
11
High stand limitation active High stand 1 (IS001)
High stand 2
 12Error crane function in stabilizer mode
90.
*
00Load limit on fly-jib overridden by 20 bar.
All load moment increasing
  movements as well as all
  lifting movements not
  possible.
91.
*
00Electronic main relief valve on fly-jib active. Fly-jib lifting is not possible any more.
92.
**
00Writing on EEPROM takes too much time.
93.
*
00Load limit of crane overridden by 20 bar.
All load moment increasing movements as well as all lifting movements not possible.
   
   
   
94.
*
00Lever not in neutral position after overload situation.

 

95.
*
00Electronic main relief valve on crane active. Crane lifting is not possible any more.
96.
*
00Power Fail (low voltage)
98.
*
00System switched off manually.
99.
*
00Programmed delay after overload.

 

Radio controller

0.00System active, all ok
1.01-16System active, analogue channel used
2.01-16System in Standby, analogue channel  1-
16 active
3.01System in Standby, emergency system on transmitter active
10.00Radio interference
01-16Radio interference, analogue channel 1-
16 active
11.01No radio signal from transmitter
20.00Programming via transmitter
01Data deleting, overwriting
21.00Loading new program

 

30.01Self check error
02Internal hardware error
03Internal synchronisation error
04Internal bus or COM error
05Error watchdog
06Error interrupt
07Error timer
08Error stack
09Internal time error
10Internal counter error
11Internal hardware self check error
12Internal plausibility check error

 

31.01Internal RAM error
02External RAM error
03EEPROM error
04FLASHPROM error
32.00Undefiniert (not used)
33.01Power supply > 35V
02Power supply < 8V
04-09undefined
10Not allowed power on dump valve
12Shortcut in emergency loop
15Shortcut on digital output 1-6
16Shortcut on digital output 7-12
17Error on digital output 1
feed back error

 

34.01-08Feedback error on analogue outputs 1-8 (power supply to valve).
35.01-08Feedback error on analogue outputs 1-8 (signal to valve).
50.01-16Lever 1-16 (analogue channel) active during start up.
51.01-16Error on analogue channel 1-16 (Comparison analogue/digital AK- DK)
52.01-08Valve error 1-8 (error input)
60.00Undefined (not used)
61.00Undefined (not used)
62.00Undefined (not used)
63.01Error input from start locking.
02Error on start locked digital channel.

 

 

 

 

If you want more information about the error codes, please contact us with the form below