HMF RCL 5100 Error Codes
Push and hold RED button to see error code, the “%” and function LEDs will light up.
*IRC – Scanreco radio controller
80% and F5 – CAN-bus connected parts
80% and F4 -Initialization of CAN-bus connected parts
80%, 85% and F4 – Pressure sensor Fly-jib output side
90% and F3 – Oil cooler error
80%, F4 and F5 – Boom pressure sensor comparison
85% and F5 – Spool sensor winch
85% and F4 – Spool sensor fly-jib extention
85%, F4 and F5 – Spool sensor fly-jib
85% and F3 – Spool sensor extention
85%, F3 and F5 – Spool sensor outer boom
85% , F3 and F4 – Spool sensor boom
90%, F3 and F5 – HDL valve error
85% and F5 – Spool sensor winch
85%, F3, F4 and F5 – Spool sensor slewing
85%, 80% and F5 – pressure sensor winch
85%, 80%, F4 and F5 – Pressure sensor fly-jib input side
85%, 80% and F3 – Pressure sensor boom
90% and F5 – Output OUT 1
90% and F4 – Output OUT 2
90%, F4 and F5 – Output OUT 3
90%, F3 and F4 – Output OUT 4
90%, 80% and F5 – Oil temp. high
90%, 85% and F4 – Incorrect set up of RCL
90%, 85%, F4 and F5 – No internal set up
90%, 85%, 80% and F4 – Internal error in AIC
90%, 85% and 80% – Error in signal from AIC
80% – CAN-bus communication (IRC)
85% – No RF-signal (IRC)
85% and 80% – Stop button pushed in (IRC)
90% – Startup error (IRC)
90% and 80% – Missing dump signal (IRC)
90% and 85% – Checksum error, (IRC)
100% – Emergency operation (IRC)
100% and 80% – Unknown error (IRC)
If you want more information about the error codes, please contact us with the form below